Description
AC INPUT
AC Input Capacity on Battery: 625VA
AC Input Voltage: 120V +/- 25%
AC Input Frequency: 50 or 60 Hz +/-10% (auto sensing)
OUTPUT
Output Voltage On Battery: Simulated sine wave at 120V +/- 5%
AC OUTPUT
AC Output Voltage: Sine wave at 120V +/-10%
AC Output Frequency: 50 or 60 Hz +/- 1%
AC Output Voltage Regulation: AVR automatically increase output voltage 15% while nominal -9% to -25% utility voltage be connected; AVR automatically decrease output voltage 13% while nominal +9% to +25% utility voltage be connected
AC Output Transfer: 2/4 milliseconds, including detection time
PROTECTION
Protection Spike : 480 Joules, 2ms
Protection Overload : UPS automatic shutdown if overload exceeds 110% nominal at 60 sec and 130% at 3 sec
Protection Unit Circuit breaker for overload & short circuit protection
Protection 10 BaseT : Network (UTP, RJ-45) compatible jacks
Protection Short Protection : UPS output cut off immediately or input circuit breaker protection
BATTERY
Battery Type : Sealed, maintenance-free lead acid batteries with 3-6 years typical lifetime
Battery Typical : 6 hours (to 90% of full capacity)
Battery Protection : Auto discharge protection
Battery Run Time 25 - 35 minutes
PHYSICAL
Weight : 7Kg (15.4lbs)
Dimension : 97x320x135mm (3.8x12.5x5.3")
ALARM
Alarm Battery Backup : Slow beeping sound (about 0.47 Hz)
Alarm Battery Low : Rapid beeping sound (about 1.82 Hz)
Alarm Overload : Continuously beeping sound
INTERFACE
Interface RS-232 : Detect battery low; Schedule UPS on/off; Display AC input/output power status
ENVIRONMENT
Environment Ambient : 3500 meters max. elevation, 0-95% humidity non-condensing, 0-40 deg C
Environment Audible <40dBA (1 meter from surface)
AC Input Capacity on Battery: 625VA
AC Input Voltage: 120V +/- 25%
AC Input Frequency: 50 or 60 Hz +/-10% (auto sensing)
OUTPUT
Output Voltage On Battery: Simulated sine wave at 120V +/- 5%
AC OUTPUT
AC Output Voltage: Sine wave at 120V +/-10%
AC Output Frequency: 50 or 60 Hz +/- 1%
AC Output Voltage Regulation: AVR automatically increase output voltage 15% while nominal -9% to -25% utility voltage be connected; AVR automatically decrease output voltage 13% while nominal +9% to +25% utility voltage be connected
AC Output Transfer: 2/4 milliseconds, including detection time
PROTECTION
Protection Spike : 480 Joules, 2ms
Protection Overload : UPS automatic shutdown if overload exceeds 110% nominal at 60 sec and 130% at 3 sec
Protection Unit Circuit breaker for overload & short circuit protection
Protection 10 BaseT : Network (UTP, RJ-45) compatible jacks
Protection Short Protection : UPS output cut off immediately or input circuit breaker protection
BATTERY
Battery Type : Sealed, maintenance-free lead acid batteries with 3-6 years typical lifetime
Battery Typical : 6 hours (to 90% of full capacity)
Battery Protection : Auto discharge protection
Battery Run Time 25 - 35 minutes
PHYSICAL
Weight : 7Kg (15.4lbs)
Dimension : 97x320x135mm (3.8x12.5x5.3")
ALARM
Alarm Battery Backup : Slow beeping sound (about 0.47 Hz)
Alarm Battery Low : Rapid beeping sound (about 1.82 Hz)
Alarm Overload : Continuously beeping sound
INTERFACE
Interface RS-232 : Detect battery low; Schedule UPS on/off; Display AC input/output power status
ENVIRONMENT
Environment Ambient : 3500 meters max. elevation, 0-95% humidity non-condensing, 0-40 deg C
Environment Audible <40dBA (1 meter from surface)