Description
AC INPUT
AC Input Capacity on Battery : 2200VA
AC Input Voltage: (+/-) 25% at line input
AC Input Frequency : 50 or 60 Hz+/-10% (auto sensing)
AC OUTPUT
AC Output Voltage Simulated sine ware at 115V +/-5%
AC Output Frequency : 50 or 60 Hz +/- 0.5%
AC Output Voltage Regulation : AVR automatically increase output voltage 15% above input voltage if -9% to -25% of nominal. AVR decrease output voltage 13% below input voltage if +9% to +25% of nominal
AC Output Transfer : 2/4 milliseconds, including detection time
PROTECTION
Protection Spike : 320 Joules, 2ms
Protection EMI/RFI : 10dB at 0.15 MHz, 50 dB at 30 MHz
Protection Overload UPS automatic shutdown if overload exceeds 110% nominal at 60 sec and 130% at 3 sec
Protection Unit Fuse for overload & short circuit protection
Protection 10 BaseT : Network (UTP, RJ-45) compatible jacks
Protection Short Protection UPS output cut off immediately or input fuse protection
BATTERY
Battery Type : Sealed, Maintenance-free lead acid, with 3 - 6 years typical lifetime
Battery Typical 4 hours (to 90% of full capacity)
Battery Protection Automatic self-test & discharge protection, replace battery indicator
BACKUP TIME
Battery Backup Time Full Load : 7 minutes
Battery Backup Time Half Load : 15 minutes
PHYSICAL
Weight : 30Kg (66lbs)
Physical Dimension : 170x448x214mm (6.7x17.6x8.4")
ALARM
Alarm Battery Backup : Slow beeping sound (about 0.47 Hz)
Alarm Battery Low Rapid beeping sound (about 1.82Hz)
Alarm Overload : Continue beeping sound
INTERFACE
Interface RS-232 Bi-directional communication port
ENVIRONMENT
Environment Ambient : 3,500 meters max. elevation, 0-95% humidity non-condensing, 0-40 deg c
Environment Audible : <40dBA (1 meter from surface)
AC Input Capacity on Battery : 2200VA
AC Input Voltage: (+/-) 25% at line input
AC Input Frequency : 50 or 60 Hz+/-10% (auto sensing)
AC OUTPUT
AC Output Voltage Simulated sine ware at 115V +/-5%
AC Output Frequency : 50 or 60 Hz +/- 0.5%
AC Output Voltage Regulation : AVR automatically increase output voltage 15% above input voltage if -9% to -25% of nominal. AVR decrease output voltage 13% below input voltage if +9% to +25% of nominal
AC Output Transfer : 2/4 milliseconds, including detection time
PROTECTION
Protection Spike : 320 Joules, 2ms
Protection EMI/RFI : 10dB at 0.15 MHz, 50 dB at 30 MHz
Protection Overload UPS automatic shutdown if overload exceeds 110% nominal at 60 sec and 130% at 3 sec
Protection Unit Fuse for overload & short circuit protection
Protection 10 BaseT : Network (UTP, RJ-45) compatible jacks
Protection Short Protection UPS output cut off immediately or input fuse protection
BATTERY
Battery Type : Sealed, Maintenance-free lead acid, with 3 - 6 years typical lifetime
Battery Typical 4 hours (to 90% of full capacity)
Battery Protection Automatic self-test & discharge protection, replace battery indicator
BACKUP TIME
Battery Backup Time Full Load : 7 minutes
Battery Backup Time Half Load : 15 minutes
PHYSICAL
Weight : 30Kg (66lbs)
Physical Dimension : 170x448x214mm (6.7x17.6x8.4")
ALARM
Alarm Battery Backup : Slow beeping sound (about 0.47 Hz)
Alarm Battery Low Rapid beeping sound (about 1.82Hz)
Alarm Overload : Continue beeping sound
INTERFACE
Interface RS-232 Bi-directional communication port
ENVIRONMENT
Environment Ambient : 3,500 meters max. elevation, 0-95% humidity non-condensing, 0-40 deg c
Environment Audible : <40dBA (1 meter from surface)